The boiler enables to download on USB key files from operation. Simply insert a blank USB into
the boiler display during operation or shortly after operation and wait for 10 seconds. The files
are stored on the USB stick. In case of any problem, send us files from the boiler operation (Pa-
rameters.txt, Boiler_log.xls and Boiler_log_old.xls). We can then analyze the operation of the
boiler from the day and the day before you have used the boiler.
15 FAULTS OF THE BOILER ATTACK WOOD & PELLET
Damage of lambda probe
The boiler must heat the lambda probe after starting of heating and the probe must show 21%
oxygen within 3 minutes. If it does not happen it is necessary to test the lambda probe in the
Test mode of the boiler, where it must reach 21% oxygen after 1 minute of heating up. If it does
not reach the desired value then it is probably damaged.
Emergency thermostat out of order
If the emergency thermostat is out of order there is the message on display. It is needed to check
it and possibly push it back However, this message is also displayed if fuse F10 on the main con-
trol board of the boiler is damaged. Fuse types are written on the transformer on the board.
The pump is not running but it indicates operation on the display
With such an error, fuse F6 on the main control board of the boiler may be damaged. Fuse types
are written on the transformer on the board.

16 BOILER MAINTENANCE

To ensure the correct boiler function during its life, it is necessary to do the maintenance. The
frequency of the maintenance depends on the frequency of operation and usage of the boiler.
The maintenance of the heating system and the boiler
The level of the water in the system has to be checked and eventually filled at least once in 14
days.
If the boiler is out of order during the winter period, the water could freeze in the system. There-
by it is better to empty the system or to fill the antifreeze mixture. Otherwise should be the wa-
ter removed from the system just in the necessary cases and for the shortest time possible.
After the end of the heating season it is necessary to clean the boiler and to replace the dam-
aged parts. Undo the ventilator two times a year and clean the radial impeller and the air cham-
ber of the ventilator.
Tightening the hinges and exchange of the sealing cord of the door
The cords of the door are losing their elasticity by the ordinary operation and thereby they de-
crease their tightness. To increase the tightness when doing the maintenance, it is possible to
change the position of the cord in direction into the boiler and to make it more pressed. When
the cord totally loses its elasticity, or when the hinges cannot be shifted further into the boiler, it
is necessary to exchange the cord. Remove the old sealing cord by a screw driver and clean the
groove, where it was placed. Take the new cord and place its ending into the horizontal parts of
the groove. Use your hand or the hammer to press the cord into the groove around the door.
Release the hinges and find the appropriate position of the hinges according to the door.