  • Page 1 WALL HUNG ELECTRIC BOILER ATTACK® ELECTRIC EASY INSTRUCTIONS FOR USE W W W . A T T A C K . S K...
  • Page 2: Table Of Contents

    Contents 8. Claims ..... . 16 1. 1. General information 1.1 Description and use....3 1.2 Advantages of boiler .
  • Page 3: General Information

    1.2 Advantages of boiler You have bought modern product direct heated electric † small dimensions, modern design boiler Electric Easy from the company ATTACK, Slovak † high efficiency 99 % Republic. We believe that our product will serve you †...
  • Page 4: Putting Into Operation

    or placed to another place. NOTICE! If you take the boiler from † The boiler has to be connected by the nut with flat ring colder environment to warmer (for sealing. example if the outside temperature is † It is necessary to connect the heating water inlet with below 0°...
  • Page 5: Main Dimensions

    1. 4 Main dimensions Dimensions in mm.
  • Page 6: Technical Data

    1.5 Technical data Boiler type Unit ATTACK ELECTRIC EASY 8 Electric parameters Total electric input Nominal heating output Nominal current 3x12 / 1x36 Voltage 3x250/400 V+N+PE/50 HZ 1x250 V+N+PE/50 Hz Nominal current max. 3x16 / 1x40 Pump input Main circuit breaker...
  • Page 7: Main Parts

    1.6 Main parts emergency thermostat control unit heating element deaerate valvel control unit holder heatmeasuring control touch buttons reservoir and display switch board for service utility water connection X2 thermomanometer boiler body boiler frame outlet pipe switch board X1 insulation of safety contactor boiler body inlet pipe...
  • Page 8: Description Of Functions

    1.7.5 Safety function of the boiler 1.7 Description of function Control unit 1.7.1 Technical description †The control unit is designed according to valid EU The boiler is designed according to valid norms and rules norms and is certified. ČSN EN and IEC. The safety of the boiler, energy saving †The control unit has a protection against below and and sound was important matter during the boiler over voltage...
  • Page 9: Circuit Diagram

    1.8 Circuit diagram Circuit diagram for the connection 1x 230 V Control unit from the face to the transformer sensor of heating water (NTC) TER 24V Č PG21 it is not a part of delivery orange green TER.TUV Legend: NTC - NTC sensor K1 - contactor TER - room thermostat X1 - switch board 1...
  • Page 10 Circuit diagram for connection to 3x230/400V Control unit from face to transformer side. sensor of heating water (NTC) TER 24V Č PG21 it is not a part of delivery green orange TER.TUV Legend: NTC - NTC sensor K1 - contactor TER - room thermostat X1 - switch board 1 HT - emergency thermostat...
  • Page 11: Control Panel

    2. Maintanance Control panel information about instantaneous/set temperature mode information breakdown information point is lighting = only 1 heating information about parameters setting 8 .0 . element is on point is not lighting = no heating element is on point is blinking = below/overvoltage in supply net point is lighting = setting short pushing...
  • Page 12: Operation Mode Service Utility Water

    Regulation is controlled on the basis of the temperature 2.3.2 Operation mode service utility water setting of heating water and hysteresis. (on the display there is ГB) Setting of heating water temperature: Set the temperature requested on the control panel using the buttons , (during setting the point between numbers are lighting) and confirm by...
  • Page 13: Setting Of Boiler Parameters

    Setting /termination of mode LE: the buttons , and choose the number of parameter Reduce the temperature requested on the control panel you want to set. By pushing you are able to set the by pushing the button to 30° C and after next pushing value of the parameter.
  • Page 14: Breakdowns

    †ČSN 07 0240:1993 - Water and low pressure steam requested (difference between the temperature of boiler boilers basic rules when the boiler start to heat and the temperature †ČSN 07 7401:1992 - Water and steam for heating requested) setting only by an authorized service man!! energetic equipments Notice: If you increase hysteresis you can reduce the †ČSN 33 1310:1990 - Electrotechnical rules.
  • Page 15: Installation Of The Room Thermostat

    loose parts in the heating water to avoid paralysation of Before mounting of the boiler it is necessary to be regulation and safety function components,including the installed supply electric cable with main switcher and pump.The boiler has to be installed in opened or closed with over current circuit breaker including starting heating system according to the normative conditions inspection revise and to have confirmed application for...
  • Page 16: Marking Of Working Scale

    Curves Dependency of expansion vessel volume and volume of heating system for temperature gradient 80/60°C Heating system pressure 2 bars Heating system pressure 1 bar Heating system pressure 0, 5 bar Volume of heating system water in time of reaching of maximal temperature of Filling overpressure of expansion vessel heating water.
  • Page 17: Maintenance

    Working features of the pump Grundfos Cesao 3 4. Termination of operation 6. Full delivery † Concerning termination of boiler operation carry out The electric boiler is delivered assembled. it by switching off the switcher in the lower part of the boiler, by switching off the main switcher on the Full delivery of electric boiler consists of: electric supply feeding.
  • Page 18: Way Of Liquidation

    10. Enclosures † Your claim is not valid without fulfilled guarantee list. 10.1 Installation of the room thermostat, see picture No. 34 9. Way of liquidation Solid waste recycling † mill board † PE bags, polystyrene binding tapes Boiler's recycling after its lifetime according to national normative waste recycling.
  • Page 19 10.2. Control unit - diagram...
  • Page 21 In case of any questions related to the processing of your personal data, please do not hesitate to contact us at tel. no. 00421 43 400 3131 or support@attack.sk. Privacy Manager: ATTACK, s. r. o., with its registered office at Dielenská Kružná 5020, 038 61 Vrútky, Slovak Re- public Tel .: +421 43 4003 101 Fax .: +421 43 3241 129...
  • Page 22 (f) Regulation (EU) 2016/679 of the European Parliament and of the Council of 27 April 2016 on the protection of natural persons with regard to the processing of personal data and on the free movement of such data, and repealing Directive 95/46/EC (General Data Protection Regulation).
  • Page 23 ATTACK, s. r. o., Dielenská Kružná 5020, 038 61 Vrútky, Slovak Republic. In the objection, it is suf- ficient to provide the name, address and the text "I hereby raise an objection to the processing of my personal data for the purposes of direct marketing"...
  • Page 25 Guarantee The company ATTACK, s.r.o. warrants for this product only if there have been met conditions of the warranty in time 24 months - 2 years - from the date of starting the boiler up. The serial num. of the boiler:...
  • Page 26 - wood pellets of 6 mm diameter, max. length 35 mm, according to DIN 51 731-HP 5 or DIN Plus  or EN 14961-2-A1 Regumat ATTACK-OVENTROP will not be installed in the system to ensure that the boiler return temperature is  at least 65 ° C during operation there is no functional thermostatic valve installed to the boiler for cooling circuit connected to the cooling wa- ...
  • Page 28 Tel: +421 43 4003 101 • Fax: +421 43 3241 129 • E-mail: kotle@attack.sk Export – tel: +421 43 4003 115 • Fax: +421 43 3241 129 • E-mail: export@attack.sk ATTACK, s.r.o. producer reserves the right to change technical parameters...