Check the detector functioning at the alleged installation place. When choosing the location of MotionProtect
Outdoor, take into account the radio signal communication range.
If the signal level is low (one bar), we cannot guarantee the stable operation of the detector. Take all possible
measures to improve the quality of the signal. At least, move the detector: even a 20 cm shift can significantly
improve the quality of signal reception.
If the detector has low or unstable signal strength even after moving, use a
Be careful when mounting the attachment panel. Excessive force during its mounting can lead to deformation of the panel and, consequently, to the
inability to install the detector or to its unreliable fixation. Attach SmartBracket with the bundled fixing tools. Using any other tools, e.g., large diameter
screws may damage the attachment panel. We do not recommend using double-sided adhesive tape for permanent mounting. The tape runs dry with
time, which can cause falling, false triggering, and detector malfunction.
Do not install the detector:
•
Opposite the trees whose leaves can be in the detection zone of the upper and lower PIR sensors of the detector.
•
Opposite the bushes higher than 80 cm.
•
Near metal objects and mirrors (they can shield the radio signal and lead to its attenuation).
•
Closer than 1 meter from the hub.
Note that MotionProtect Outdoor does not detect movement behind the glass. Therefore, do not install the detector
in locations where glass objects can obstruct the detector's view. For example, in places where a glass door can
obstruct the view of the device.