A
COMIST 122 DSPNM
845
COMIST 180 DSPNM
875
COMIST 250 DSPNM
1035 555 480 1260 580 680 385 1750 320÷500 320 273 440 440 400÷540 M20 330
COMIST 300 DSPNM
1035 555 480 1260 580 680 385 1750 320÷500 320 273 440 440 400÷540 M20 330
TeCHniCaL fUnCTiOnaL feaTUres
•
Burners with alternate natural gas/fuel oil supply.
•
Operation with two progressive power stages.
•
Possibility of power modulation operation with installation on
PID modulation automatic regulator control panel (to be ordered
separately with the specific modulation kit).
•
Ability to operate with any type of combustion chamber.
•
Air-gas mixing at blast-pipe and high pressure mechanical
atomisation of fuel using nozzle.
•
Possibility to obtain great combustion values through combustion
air and combustion head regulation.
•
Easier maintenance thanks to the possibility to remove the
mixing and atomization unit without separating the burner from
the boiler.
A1
A2
B
B1
B2 B3
450 395 1000 450 550 310 1490 195÷455 227 220 320 320 280÷370 M12 230
460 415 1230 450 780 485 1700 330÷540 260 245 460
0006080118_201311
1
Gas pressure switches
2
Safety valves and pilot train operation
3
Air pressure switch
4
UV photocell
5
Electromagnet
6
Insulating seal
7
Burner coupling flange
8
Pre-heater tank
9
Pump motor
10
Electrical panel
11
Pump
12
Pressure control valve
13
Safety valve
14
Operating valve
15
Screw for regulating air supply to combustion head
16
Combustion head
C
D
E
•
Air minimum and maximum flow rate regulation by means of
electric servomotor with pause closure of shutter to prevent any
heat dispersion to flue.
•
Valve seal control according to European Standard EN676.
•
Preset for fuel automatic switching.
•
nozzle to be ordered separately according to the required
flow rate.
6 / 44
F
I
I1
L
M
-
400
M20 300
N