baltur COMIST 180 DSPNM User Instruction Manual page 12

Progressive/modulating two-stage mixed gas/fuel oil burners
Hide thumbs Also See for COMIST 180 DSPNM:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
COnneCTiOn Diagram Of mULTiPLe BUrners TO THe meDiUm PressUre gas sUPPLY neTWOrK
COnneCTiOn Diagram Of One BUrner TO THe meDiUm PressUre gas sUPPLY neTWOrK
1 - Reduction and measurement control unit
2 - Shut-off cock
3 - Gas filter
4 - Pressure reducer
5 - Meter
6 - Emergency shut-off cock (installed outside)
7 - Ball cock
8 - Gas filter
9 - Pressure reducer or regulator/stabilizer (according to the case)
10 - Vibration-proof joint
11 - Flange coupling
D = Distance between gas valves and pressure stabilizer (approx. 1.5 ÷ 2 m)
1 - Reduction and measurement control unit
2 - Shut-off cock
3 - Gas filter
4 - Pressure reducer
5 - Meter
6 - Release into the atmosphere with flame trap wire gauze
7 - Possible automatic overflow valve
(it must discharge outside in a suitable place)
8 - Emergency shut-off cock (installed outside)
9 - Ball cock
10 - Vibration-proof joint
11 - Flange coupling