Siemens SINAMICS G110D Series Getting Started page 29

Distributed converter
Hide thumbs Also See for SINAMICS G110D Series:
Table of Contents

Advertisement

Table 3- 14
Motor connector
Power
cable
Belcom
rating
size
"DESINA"
Cable No.
0.75 kW
1 mm
13EBN17Z08P
2
18 AWG
1.50 kW
3.00 kW
2.5 mm
13EBN13Z08P
2
14 AWG
4.00 kW
5.50 kW
4 mm
13EBN11Z08P
2
12 or 10
7.50 kW
AWG
4 x crimps are required for each inverter for the motor connections; use 75°C copper wire only
Table 3- 15
Temperature sensor and EM brake
Power
cable
rating
size
0.75 kW
1 mm
2
18 AWG
1.50 kW
3.00 kW
2.5 mm
2
14 AWG
4.00 kW
5.50 kW
4 mm
2
12 or 10
7.50 kW
AWG
2 x crimps are required for each auxiliary signal pair; use 75°C copper wire only
Connection specifications
Danger to life when live parts are touched in the motor terminal box
Hazardous voltage can be present on the pins for temperature sensor and motor holding
brake. Touching live parts on the motor cable and in the motor terminal box can lead to
death due electrical shock.
• Keep the motor terminal box closed whenever the mains is applied to the converter.
• Insulate the cables that are not used.
• Use appropriate insulation on the cables.
SINAMICS G110D
Getting Started, 07/2016, FW V3.63, A5E38556288B AA
All connector parts are Harting Q8/0
Shell
Harting Q8/0
0912 008
3001
Belcom
Temperature sensor pair
"DESINA"
Crimp size
Cable No.
13EBN17Z08P
0.75 mm
20 AWG
13EBN13Z08P
1 mm
2
18 AWG
13EBN11Z08P
1 mm
2
18 AWG
DANGER
Crimp size
Crimp number
1 mm
0933 000 6105
2
18 AWG
2.5 mm
0933 000 6102
2
14 AWG
4 mm
0933 000 6107
2
12 or 10
AWG
Crimp number
0933 000 6114
2
0933 000 6105
0933 000 6105
Electrical Installation
3.2 Cables and connections
Hood
Gland/Seal
1912 008 0502
1912 000 5057
1912 008 0528
Lapp
MS-SC-
M25x1.5
53112640
EM Brake pair
Crimp size
Crimp number
0.75 mm
0933 000 6114
2
20 AWG
1 mm
0933 000 6105
2
18 AWG
1.5 mm
0933 000 6104
2
18 AWG
29