Electrical Installation
3.3 Configuring the AS-i slave
Note
Profile 3.0
Under AS-i Profile 3.0 it is possible to address 62 digital or 62 analog slave devices or a
combination of both digital and analog but not exceeding a total of 62 slave devices. This is
accomplished by using the A/B address system. For example, two slaves can assigned as
number 1 slave device, by assigning them as 1A and 1B.
The addresses of the slave devices do not have to be sequential, for example the first slave
device can have the address 21, the next 10.
Prior to the installation and commissioning of the Inverter, the AS-i communications and
devices have to be set-up correctly. The equipment shown in the table below will be
necessary for the successful integration of more than one Inverter onto the AS-i bus network.
Table 3- 20
Equipment for installation of SINAMICS G110D (AS-i)
Item
Address cable
AS-i address programmer
AS-i connection kit
32
Order Number
3RK1901-3HA01
3RK1904-2AB01
3RK1901-1NR21
Getting Started, 07/2016, FW V3.63, A5E38556288B AA