Command
Output Configuration (continued)
Screen Saver
Set mode
View mode
Set screen saver duration
before output sync timeout
View screen saver duration
before output sync timeout
View screen saver status
OSD Menu Duration
Set OSD duration
View OSD duration
KEY:
X2*
= Output sync or OSD menu timeout
X4)
= Screen saver mode
X6#
= Screen saver status
Logos
Logo Assignment
Select image file
NOTES:
filename
The
must consist of a full path name if the file is not in the
The file name must include the extension (.png, .bmp, .jpg, .gif, .tif, and so on).
/Graphics
If the file is not in the
/Logo123.bmp
Example:
View selected logo file
KEY:
X4#
= User logo number
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
* X4)
E
}
M1
SSAV
SsavM1*
E
}
X4)]
M1 SSAV
E
1* X2*
}
Ssav T1* X2*]
T
SSAV
E
1
}
X2*]
T
SSAV
E
}
X6#]
S1SSAV
Verbose modes 2 and 3:
Ssav S 1* X6# ]
EX2*
}
MDUR
Mdur
E
}
X2*]
MDUR
Number of seconds before output sync or the OSD menu times out.
1
through
0
=
60
= Default for the
501
= Output sync never times out (default for SSAV command).
1
= Black screen (default)
2
= Blue screen with OSD text
3
= User image on black screen
0
= Active input detected, timer not running
1
= No active input, timer running, output sync still active
2
= No active input, timer expired, output sync disabled
E A X4#
filename
}
,
LOGO
LogoA X4#
directory, include a
.
E A X4#
filename ]
}
LOGO
1
through
101
= No signal, screen saver user logo or image is displayed.
201
= User HDCP logo displayed
IN1804 Seamless Scaling Switchers • SIS Configuration and Control
Additional Description
X4)]
Set the screen saver mode for the
output to
View the screen saver mode
output. Default =
Set the screen saver timeout duration to
X2*
seconds. Default =
View screen saver timeout duration
View screen saver status
X2*]
Set the OSD menu duration to
View the OSD menu duration.
500
seconds, in 1-second increments
Output sync is instantly disabled with no active video from the
selected input (not allowed for
MDUR
command.
filename ]
,
Assign logo
/Graphics
directory.
/
before the filename to indicate that it is in the root directory.
View the logo filename assigned to logo
X4#
.
16
. The response is three digits padded with leading zeros.
X4)
.
X4)
for the
1
(black).
501
(never).
X6#
.
X2*
.
MDUR
command).
filename
to logo slot
X2*
.
X4#
.