A. Technical Appendix
A.1
Technical specifications of the field bus node CP FB5-E
General
Temperature range
– operation
– storage/transport
Relative humidity
Protection class as per EN 60 529
Plug connector plugged in or fitted with protec-
tive cap
Protection against explosion
(as per EU guideline 94/9/EG, EN 50021 and
EN 50281-1-1). Do not disconnect electrical
connections which are under tension.
Operating voltage Electronic components and input modules
Operating voltage connection (Pin 1)
– rated value
– tolerance
Current consumption
– Pin 1 node FB5-E
– Complete electronics of the CP system
Residual ripple
Power failure bridging time
Electromagnetic compatibility
Interference emission
– tested as per EN 55011
Resistance to interference
– tested as per EN 50082-2
Festo P.BE-CP-FB5-E-EN en 0112a
- 5 °C ... + 50 °C
-20 °C ... + 70 °C
95%, non condensing
IP 65
II 3 G/D EEx nA II T5 X - 5 °C ≤Ta ≤+ 50 °C
T 80 °C IP65 (year of manufacture see Ex-identifi-
cation on the product)
Plugs or adapters of the electric connections
must comply at least with protection class IP64!
DC 24 V
20,4 .. 26,4 V
250 mA
see "CP system" manual, Chapter 3.1.2, Table of
current consumption
4 Vpp (within tolerance)
20 ms
Limit values class B*)