2. Commissioning
2.2

Festo fieldbus

2.2.1 Configuration

Procedure
2-4
The field bus configurator in the FST software supports you in
creating the NOMINAL configuration. Menu control and oper-
ation of the FST software is described in the appropriate FST
manual.
1. Enter the field bus address of the field bus slave (CP
system).
2. Select the type of field bus slave ("Valve terminal 10" for
CP system).
3. Enter the number of assigned inputs/outputs in bytes
under IW/OW. The number of IW and OW must be the
same.
Please note
The entry mask for the field bus configurator shows IW and
OW on the screen. This means input and output words with
8 bits each. Enter 2 IW and 2 OW per string (16 inputs and
16 outputs).
Festo P.BE-CP-FB5-E-EN en 0112a