2. Commissioning
POWER
POWER V
1
1
String unused, but address range assigned (reserved)
E = input; A = output
Fig. 2/5: Example – addressing with a 07KR91 central processing unit
2-10
The 07KR91 central processing unit ascertains the configur-
ation of the CS 31 system bus when it is switched on and
does not require any settings.
Please note
With system flag KW 00,09, program processing can be
blocked until the specifiednumber of I/O modules (incl.
CP systems) is available on the CS 31 system bus.
Example of addressing with the 07KR91 central pro-
cessing unit
Address 12 is set in the CP node. The CP system occupies 3
CS 31 bus addresses (48 O/48 I).
A12,0 ... A12,15
A14,0 ... A14,15
E12,0 ... E12,15
E14,0 ... E14,15
Festo P.BE-CP-FB5-E-EN en 0112a