CP Plus Indigo JRC-27F User Manual page 107

Without hdd
Table of Contents

Advertisement

Please refer to the following sheet for detailed information.
Parameter
Enable
Period
Interval
Sensitivity
Record channel
Delay
PTZ Activation
Tour
Show message
Send Email
Alarm upload
Buzzer
You need to check the box to enable motion detection function.
Please select a channel from the dropdown list.
Motion detection function becomes activated in the specified periods.
See Figure 5.29.
There are six periods in one day. Please draw a circle to enable
corresponding period.
Click OK button, system goes back to motion detection interface; please
click save button to exit.
System only memorizes one event during the anti-dither period. The
value ranges from 5s to 600s.
There are six levels. The sixth level has the highest sensitivity.
System auto activates motion detection channel(s) to record once an
alarm occurs. Please note you need to set motion detect record period
and go to Storage → Schedule to set current channel as schedule
record.
System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.
Here you can set PTZ movement when alarm occurs. Such as go to
preset X. See Figure 5.30.
You need to check the box here to enable this function. System begins
1-wiindow or multiple-window tour display among the channel(s) you
set to record when an alarm occurs.
System can pop up a message to alarm you in the local host screen if
you enabled this function.
If you enabled this function, System can send out an email to alert you
when an alarm occurs.
System can upload the alarm signal to the server (Including alarm
server.
Check the box here to enable this function. The buzzer beeps when an
alarm occurs.
Function