Selecting a test pattern

Many test patterns are available to assist with the configuration of the projector and to diagnose any
issues that may occur.
1. From the display panel, use the arrows to select Test Pattern.
You can also select the test patterns from MENU > Test Pattern.
2. Scroll through the list of test patterns.
3. Select the required test pattern.
4. To confirm your selection, select Enter.

Aligning the boresight

The boresight adjustment balances the tilt of the lens mount to compensate for screen-to-projector
tilt.
1. Display the boresight test pattern.
a) On the remote keypad, press Test.
On the built-in keypad, press the soft key that displays Test on the display panel
b) To cycle to Boresight, press the Up Arrow key.
c) Press Enter.
2. Focus the image on cross-hair image I.
3. Evaluate the focus on cross-hair image II and III.
If all three images are in focus, no further action is required.
If boresight is required, continue to step 4.
The adjustment screws (A) on the lens mount affects the corresponding cross-hairs on the test
pattern.