4. Use the arrows to adjust the offset to display a square image on the screen, with minimal
projector aiming error.
5. To exit to the home page, select Back.

Resetting the lens to home position

Realign the lens to the home position after the lens has been offset and out of alignment.
1. Select LENS OFFSET.
You can also select MENU > Configuration > Lens Settings > Lens Offset.
2. To reset the lens to the default home position, select Enter.
3. To confirm the reset, select OK.

Selecting a test pattern

Many test patterns are available to assist with the configuration of the projector and to diagnose any
issues that may occur.
1. From the display panel, use the arrows to select Test Pattern.
You can also select the test patterns from MENU > Test Pattern or pressing N on the IR
remote.
2. Scroll through the list of test patterns.
3. Select the required test pattern.
4. To confirm your selection, select Enter.

Adjusting boresight

The boresight adjustment balances the tilt of the lens mount to compensate for screen-to-projector
tilt.
Caution! If not avoided, the following could result in minor or moderate injury.
Do not look directly into the lens when the light source is on. The extremely high brightness can
cause permanent eye damage.
1. Close the shutter on the projector.
2. Unlock the three lens mount stabilization screws.