Sign In
Upload
Manuals
Brands
DSC Manuals
Control Panel
MAXSYS PC4020
DSC MAXSYS PC4020 Manuals
Manuals and User Guides for DSC MAXSYS PC4020. We have
8
DSC MAXSYS PC4020 manuals available for free PDF download: Installation Manual, Instruction Manual, Manual, System Manual
DSC MAXSYS PC4020 Installation Manual (80 pages)
v3.5 DLS2002 or higher
Brand:
DSC
| Category:
Control Panel
| Size: 2 MB
Table of Contents
Limited Warranty
2
Warning Please Read Carefully
2
Table of Contents
3
Section 1: Introduction
5
Out of the Box
5
Specifications and Features
5
Section 2: Installation and Wiring
6
Planning the System
6
Terminal Descriptions
6
Wire Routing for Power and Non-Power Limited
6
Current Ratings - Alarm Control Panel and Modules
6
Combus Operation and Wiring
7
Zone Wiring
8
Specialized Zone Wiring
8
Programmable Output Wiring
9
AML Device Wiring
9
Wiring Powered Devices (AUX, SAUX+)
10
Telephone Line Wiring
10
Bell Output Wiring (BELL and BELL )
11
Earth Ground Wiring
11
Applying Power (AC and Battery)
11
Lithium Batteries
12
Section 3: How to Program
13
Introduction to Programming
13
Programming by Reference Number
13
Programming Decimal Data
13
Programming Hexadecimal Data
14
Programming Toggle Options
14
Section 4: Module Enrollment
15
Enrolling Keypads and Modules
15
Deleting Modules
15
Confirming Modules
15
Enrolling AML Devices
16
Section 5: Partitions and Zones
17
Zone Supervision
17
Creating Partitions
17
Adding Zones to Partitions
18
Zone Programming
18
Zone Types
19
Bypass Grouping
21
Section 6: Keypad Operation
23
Partition Keypads
23
Global Keypads
23
Keypad Toggle Options
23
Keypad Time-Out
24
Keypad Blanking
24
Fire, Auxiliary and Panic Keys
24
Keypad Lockout
24
Keypad Tampers
25
Alarm Memory Display
25
Zone Bypass Display
25
Function Key Programming
25
Section 7: Installer and Access Codes
27
Installer's Code
27
Installer-Programmed Access Codes
27
Programming Access Codes
27
Modify an Existing Code
29
Change User Code Options
29
Delete an Existing Code
29
Special Codes
30
Guard Code
30
Access Code Options
30
Access Levels
31
Section 8: Arming and Disarming
32
Arming and Disarming Options
32
Automatic Arming
32
Close Time Timer (CTT Duration)
32
Disarm Delay
32
Dual Users for Disarming
33
Section 9: Entry and Exit Delay
34
Entry and Exit Delay Times
34
Entry and Exit Delay Options
34
Section 10: System Programming
35
AC/DC Power Options
35
Bell Circuit Supervision
35
Clock Options
35
Event Messages
35
Swinger Shutdown
36
Tampers
36
Telephone Line Supervision
36
Test Transmissions
36
Transmission Delay
37
Cross Zone (Police Code) Alarm
37
System Label
37
Hourly Print
37
Section 11: Programmable Outputs
38
Main Panel Outputs
38
Programming Output Options for Modules
38
Programmable Output Options
38
Output Pulse Times
41
Section 12: Communications Programming
42
Telephone Numbers
42
Account Numbers
42
Dialing Parameters
42
Communicator Toggle Options
42
Dialer Direction
44
Communicator Formats
44
Reporting Codes
45
Section 13: Downloading
46
Downloading Options
46
Periodic Call-Up
46
PC-Link
46
Section 14: Event Scheduling
47
Date Schedules
47
Holiday Groups
47
Open/Close Suppression
47
Arming/Disarming Schedules
48
Scheduled AMS-220/220T Smoke Detector Test
48
CTT Schedule
48
Seismic Schedule
48
Section 15: LINKS Communications
49
LINKS1000 (Cellular Communications)
49
LINKS2XXX (Long-Range Radio Communications)
49
T-Link TCP/IP Communications)
49
Section 16: Diagnostics and Troubleshooting
50
General Diagnostics
50
Restoring Factory Default Programming
50
Hardware Reset
50
Viewing Trouble Conditions
50
System Fault Squawk
51
Section 17: Local, Central & Remote Station Fire Installation Instructions
53
Introduction
53
Hardware Description and Specifications
53
Section 18: Fire Zone Types
55
Partitions and Fire System Configuration
55
Standard Fire Zone
55
Delayed Fire Zone
55
Auto Verify Fire
56
Waterflow Zone
56
Fire Supervisory Zone
57
PC4701 Zones
57
4-Wire Smoke Detector Zones
57
AMS-220 Addressable Smoke Detector Zones
57
AMP-702 Addressable Fire Point Module
57
Section 19: PC4702BP Output Programming
58
Alarm Notification Output Types
58
Programming PC4702BP Outputs
58
Fire Bell Options
58
Partitions and Fire System Configuration
58
Section 20: Fire System Operation
60
Manual Signal Silence
60
Automatic Signal Silence (Bell Cut-Off)
60
Signal Silence Inhibit Timer (Fire Silence Delay)
60
Fire System Reset
60
Manual Sensor Reset ([*][7][2])
60
Subsequent Alarm Operation
60
Fire Silence/Reset User Codes
61
Auto-Scroll LCD Keypad Display
61
Fire Trouble Conditions
61
AC Delays
62
Bypassing Fire Zones
62
Fire Drill Feature
62
Fire Inspector Test
62
Testing AMS-220/220T Smoke Detectors
63
Lamp Test
63
PC4701 Remote Station Alarm/Trouble Relays
63
Fire Reporting Codes
63
Upload/Download Considerations
64
Section 21: Listing Requirements
65
UL Listed Commercial Burglary and Resi- Dential Burglary/Fire Installations
65
Commercial Fire Alarm Installations
65
ULC Listing Requirements
66
Appendix A: Wiring Diagrams
67
Fire Alarm
72
Appendix B: Reporting Codes
73
Appendix C: Zone Reporting Codes
76
ASCII Characters
77
Fcc Compliance Statement
79
Advertisement
DSC MAXSYS PC4020 Installation Manual (60 pages)
v3.3 Security System
Brand:
DSC
| Category:
Control Panel
| Size: 1 MB
Table of Contents
Limited Warranty
2
Warning Please Read Carefully
2
Table of Contents
3
Section 1: Introduction
5
Out of the Box
5
Specifications and Features
5
Section 2: Installation and Wiring
6
Planning the System
6
Terminal Descriptions
6
Wire Routing for Power and Non-Power Limited
6
Current Ratings - Alarm Control Panel and Modules
6
Combus Operation and Wiring
7
Zone Wiring
8
Specialized Zone Wiring
9
Programmable Output Wiring
9
AML Device Wiring
9
Wiring Powered Devices (AUX, SAUX+)
10
Telephone Line Wiring
11
Bell Output Wiring (BELL and BELL )
11
Earth Ground Wiring
11
Applying Power (AC and Battery)
11
Lithium Batteries
12
Section 3: How to Program
13
Introduction to Programming
13
Programming by Reference Number
13
Programming Decimal Data
13
Programming Hexadecimal Data
14
Programming Toggle Options
14
Section 4: Module Enrollment
15
Enrolling Keypads and Modules
15
Deleting Modules
15
Confirming Modules
16
Enrolling AML Devices
16
Section 5: Partitions and Zones
17
Zone Supervision
17
Creating Partitions
17
Adding Zones to Partitions
18
Zone Programming
18
Zone Types
19
Section 6: Keypad Operation
22
Partition Keypads
22
Global Keypads
22
Keypad Toggle Options
22
Keypad Time-Out
23
Keypad Blanking
23
Fire, Auxiliary and Panic Keys
23
Keypad Lockout
23
Keypad Tampers
24
Alarm Memory Display
24
Zone Bypass Display
24
Function Key Programming
24
Section 7: Installer and Access Codes
26
Installer's Code
26
Installer-Programmed Access Codes
26
Programming Access Codes
26
Modify an Existing Code
28
Change User Code Options
28
Delete an Existing Code
29
Special Codes
29
Guard Code
30
Access Code Options
30
Access Levels
30
Section 8: Arming and Disarming
31
Arming and Disarming Options
31
Automatic Arming
31
Section 9: Entry and Exit Delay
32
Entry and Exit Delay Times
32
Entry and Exit Delay Options
32
Section 10: System Programming
33
AC/DC Power Options
33
Bell Circuit Supervision
33
Clock Options
33
Event Messages
34
Swinger Shutdown
34
Tampers
34
Telephone Line Supervision
35
Test Transmissions
35
Transmission Delay
35
Cross Zone (Police Code) Alarm
36
System Label
36
Hourly Print
36
Section 11: Programmable Outputs
37
Main Panel Outputs
37
Programming Output Options for Modules
37
Programmable Output Options
37
Output Pulse Times
39
Section 12: Communications Programming
41
Telephone Numbers
41
Account Numbers
41
Dialing Parameters
41
Communicator Toggle Options
41
Dialer Direction
43
Communicator Formats
43
Reporting Codes
44
Section 13: Downloading
45
Downloading Options
45
Periodic Call-Up
45
PC-Link
45
Section 14: Event Scheduling
46
Date Schedules
46
Holiday Groups
46
Open/Close Suppression
46
Arming/Disarming Schedules
47
Scheduled AMS-220/220T Smoke Detector Test
47
Section 15: LINKS Communications
48
LINKS1000 (Cellular Communications)
48
LINKS2XXX (Long-Range Radio Communications)
48
T-Link TCP/IP Communications)
48
Section 16: Diagnostics and Troubleshooting
49
General Diagnostics
49
Restoring Factory Default Programming
49
Hardware Reset
49
Viewing Trouble Conditions
49
System Fault Squawk
50
Appendix A: Reporting Codes
52
Appendix B: Zone Reporting Codes
55
Appendix C: ASCII Characters
56
Fcc Compliance Statement
59
DSC MAXSYS PC4020 Installation Manual (52 pages)
Brand:
DSC
| Category:
Security System
| Size: 1 MB
Table of Contents
Warning Please Read Carefully
2
Table of Contents
3
Section 1: Introduction
5
Out of the Box
5
Specifications and Features
5
Section 2: Installation and Wiring
6
Planning the System
6
Terminal Descriptions
6
Current Ratings - Alarm Control Panel and Modules
7
Combus Operation and Wiring
7
Zone Wiring
8
Specialized Zone Wiring
9
Programmable Output Wiring
10
AML Device Wiring
10
Wiring Powered Devices (AUX, SAUX+)
11
Telephone Line Wiring
11
Bell Output Wiring (BELL and BELL )
11
Earth Ground Wiring
11
Applying Power (AC and Battery)
12
Lithium Batteries
12
Section 3: How to Program
13
Introduction to Programming
13
Programming by Reference Number
13
Programming Decimal Data
13
Programming Hexadecimal Data
14
Programming Toggle Options
14
Section 4: Module Enrollment
15
Enrolling Keypads and Modules
15
Deleting Modules
15
Confirming Modules
16
Enrolling AML Devices
16
Section 5: Partitions and Zones
17
Zone Supervision
17
Creating Partitions
17
Adding Zones to Partitions
18
Zone Programming
18
Section 6: Keypad Operation
22
Partition Keypads
22
Global Keypads
22
Keypad Time-Out
22
Keypad Blanking
23
Fire, Auxiliary and Panic Keys
23
Keypad Lockout
23
Keypad Tampers
23
Alarm Memory Display
23
Zone Bypass Display
24
Function Key Programming
24
Section 7: Installer and Access Codes
26
Installer's Code
26
Other Access Codes
26
Guard Code
26
Access Code Options
26
Access Levels
27
Section 8: Arming and Disarming
28
Arming and Disarming Options
28
Automatic Arming
28
Section 9: Entry and Exit Delay
29
Entry and Exit Delay Times
29
Entry and Exit Delay Options
29
Section 10: System Programming
30
AC/DC Power Options
30
Bell Circuit Supervision
30
Clock Options
30
Event Messages
31
Swinger Shutdown
31
Tampers
31
Telephone Line Supervision
31
Test Transmissions
31
Transmission Delay
32
Cross Zone (Police Code) Alarm
32
System Label
32
Hourly Print
32
Section 11: Programmable Outputs
33
Main Panel Outputs
33
Programmable Output Options
33
Output Pulse Times
35
Section 12: Communications Programming
36
Telephone Numbers
36
Account Numbers
36
Dialing Parameters
36
Communicator Toggle Options
36
Dialer Direction
38
Communicator Formats
38
Reporting Codes
39
Section 13: Downloading
40
Downloading Options
40
Periodic Call-Up
40
PC-Link
40
Section 14: Event Scheduling
41
Date Schedules
41
Holiday Groups
41
Open/Close Suppression
42
Arming/Disarming Schedules
42
Scheduled AMS-220/220T Smoke Detector Test
42
Section 15: LINKS Communications
43
LINKS1000 (Cellular Communications)
43
LINKS2XXX (Long-Range Radio Communications)
43
Section 16: Diagnostics and Troubleshooting
44
General Diagnostics
44
Restoring Factory Default Programming
44
Hardware Reset
44
Viewing Trouble Conditions
44
System Fault Squawk
45
Appendix A: Reporting Codes
46
Appendix B: Zone Reporting Codes
48
Appendix C: ASCII Characters
49
Limited Warranty
52
Advertisement
DSC MAXSYS PC4020 Instruction Manual (40 pages)
Security System V3.2
Brand:
DSC
| Category:
Control Panel
| Size: 0 MB
Table of Contents
Fcc Compliance Statement
2
Important Information
2
Table of Contents
3
Introduction
5
Section 1: General System Operation
6
Getting to Know Your System
6
Arming Your System
7
Alternate Arming Methods
8
Disarming Your System
9
Alarm Memory
10
What to Do if an Alarm Sounds
10
Bypassing Zones
11
Viewing Trouble Conditions
12
Section 2: Access Codes
13
Programming a New Access Code
13
Modifying an Existing Code
15
Changing User Code Options
16
Access Code Label Options
16
Deleting an Existing Code
18
Special Codes
18
Installer Programmed Codes
19
Section 3: System Administration
20
Turning on Quick Arm
20
Turning on Quick Exit
20
Controlling Automatic Arming
20
Setting the Time and Date
21
Activating Door Chime
22
Viewing the Event Buffer
22
Command Outputs 1-8
22
Changing Keypad Settings
23
Downloading Options
23
PC-LINK Enable Option
24
Audio Options
24
Turning Background Music on or off
24
Section 4: Access Control
25
About Access Card Readers (PC4820 Modules)
25
Programming Access Cards (PC4820 Modules)
26
Searching Using Access Card Numbers (PC4820 Modules)
28
Adding User Telephone Numbers (PC4850 Modules)
28
Adding Tenant Codes for Users (PC4850 Modules)
29
Section 5: Testing and Maintenance
30
Performing a Walk Test
30
Performing a System Test
31
Performing a Lamp Test (PC4216)
31
System Maintenance
31
Section 6: Fire Safety
32
Fire Alarm Operation
32
Guidelines for Locating Smoke Detectors
32
Household Fire Safety Audit
34
Fire Escape Planning
34
Appendix A - Special Characters
36
Limited Warranty
37
Out of Warranty Repairs
37
Warning Please Read Carefully
38
Motion Detectors
38
Power Failure
38
Telephone Lines
38
Component Failure
38
System Users
38
Smoke Detectors
38
DSC MAXSYS PC4020 Manual (40 pages)
Brand:
DSC
| Category:
Security System
| Size: 0 MB
Table of Contents
Table of Contents
3
Introduction
5
Section 1: General System Operation
6
Getting to Know Your System
6
Arming Your System
7
Alternate Arming Methods
8
Disarming Your System
9
Alarm Memory
10
What to Do if an Alarm Sounds
10
Bypassing Zones
11
Viewing Trouble Conditions
12
Section 2: Access Codes
13
Programming a New Access Code
13
Modifying an Existing Code
15
Changing User Code Options
16
Access Code Label Options
16
Deleting an Existing Code
18
Special Codes
18
Installer Programmed Codes
19
Section 3: System Administration
20
Turning on Quick Arm
20
Turning on Quick Exit
20
Controlling Automatic Arming
20
Setting the Time and Date
21
Activating Door Chime
22
Viewing the Event Buffer
22
Command Outputs 1-8
22
Changing Keypad Settings
23
Downloading Options
23
PC-LINK Enable Option
24
Audio Options
24
Turning Background Music on or off
24
Section 4: Access Control
25
About Access Card Readers (PC4820 Modules)
25
Programming Access Cards (PC4820 Modules)
26
Searching Using Access Card Numbers (PC4820 Modules)
28
Adding User Telephone Numbers (PC4850 Modules)
28
Adding Tenant Codes for Users (PC4850 Modules)
29
Section 5: Testing and Maintenance
30
Performing a Walk Test
30
Performing a System Test
31
Performing a Lamp Test (PC4216)
31
System Maintenance
31
Section 6: Fire Safety
32
Fire Alarm Operation
32
Guidelines for Locating Smoke Detectors
32
Household Fire Safety Audit
34
Fire Escape Planning
34
Appendix A - Special Characters
36
Dsc MAXSYS PC4020 Instruction Manual (41 pages)
Brand:
Dsc
| Category:
Security System
| Size: 0 MB
Table of Contents
Warning Please Read Carefully
2
Audio Help
7
Arming Your System
7
Arming Without Entry Delay
9
Quick Arm
9
Alarm Memory
11
What to Do if an Alarm Sounds
11
Viewing Trouble Conditions
13
Programming a New Access Code
14
Program Code
15
Edit User Name
15
Modifying an Existing Code
16
Changing Access Codes
17
Changing User Code Options
17
Access Code Label Options
17
Deleting an Existing Code
19
Special Codes
19
Installer Programmed Codes
20
Setting the Time and Date
22
Activating Door Chime
23
Viewing the Event Buffer
23
Changing Keypad Settings
24
Downloading Options
24
PC-LINK Enable Option
25
Audio Options
25
Turning Background Music on or off
25
About Access Card Readers (PC4820 Modules)
26
Programming Access Cards (PC4820 Modules)
27
Access Level
27
User Options
28
Searching Using Access Card Numbers (PC4820 Modules)
29
Adding User Telephone Numbers (PC4850 Modules)
29
Adding Tenant Codes for Users (PC4850 Modules)
30
Performing a Walk Test
31
Fire Alarm Operation
33
Guidelines for Locating Smoke Detectors
33
Limited Warranty
38
Out of Warranty Repairs
38
Fcc Compliance Statement
39
Additional Information
39
DSC MAXSYS PC4020 System Manual (36 pages)
Brand:
DSC
| Category:
Security System
| Size: 0 MB
Table of Contents
Table of Contents
2
PC4020 Control Panel Wiring Diagram __________________ II Terminal Connections
3
Introduction
3
System Overview Maximum System Capabilities
4
Installation and Wiring
5
RF Zones — Summary
6
Battery Troubles
7
Mounting the Panel
8
Hardware Reset of Memory to Factory Defaults
9
PC4020 Main Board Specifications Control Panel
10
Module Specifications PC4108 Expansion Module
11
AC" Power Terminals
12
Telephone Terminals "TIP", "RNG", "T-1" and "R-1
13
Partitions
14
System Master Code Functions
17
PC4700 Fire Module
19
Downloading with an On-Site Computer
27
Grade B Central Station and Grade a Police Connect
28
Appendix A List of Available ASCII Characters
29
Appendixb List of Diagnostics
30
Limited Warranty
31
Out of Warranty Repairs
31
Important Information
32
DSC MAXSYS PC4020 Instruction Manual (3 pages)
Brand:
DSC
| Category:
Security System
| Size: 0 MB
Advertisement
Related Products
DSC Maxsys PC4020 - V3.3
DSC Mounting Plate HS-MP Series
DSC SG SECURITY MLR2-DV
DSC AFD2000
DSC CFP-102
DSC HS2064 E
DSC HS2128 E
DSC HS2LCDWFP
DSC HS2LCDWFV
DSC Categories
Security System
Security Sensors
Keypad
Control Panel
Cell Phone
More DSC Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL