IBM Power System Series Problem Analysis, System Parts, And Locations page 58

Hide thumbs Also See for Power System Series:
Table of Contents

Advertisement

Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
• CPU Core Func 13 (0xD4)
• CPU Core Func 14 (0xD5)
• CPU Core Func 15 (0xD6)
• CPU Core Func 16 (0xD7)
• CPU Core Func 17 (0xD8)
• CPU Core Func 18 (0xD9)
• CPU Core Func 19 (0xDA)
• CPU Core Func 20 (0xDB)
• CPU Core Func 21 (0xDC)
• CPU Core Func 22 (0xDD)
• CPU Core Func 23 (0xDE)
• CPU Core Func 24 (0xDF)
44 Power Systems: Problem analysis, system parts, and locations for the 5104-22C, 9006-12P, 9006-22C, and
9006-22P
Event description
• IERR
• Transition to Non-recoverable
• Predictive Failure
• FRB1 BIST Failure
• FRB2 Hang In POST Failure
• FRB3 Processor Startup
Initialization Failure
• Configuration Error
• SMBIOS Uncorrectable CPU
Complex Error
• Processor Disabled
• Terminator Presence Detected
• Machine Check Exception
• Correctable Machine Check
Error
• State Deasserted
• Device Disabled
• Transition to Critical from Less
Severe
• Transition to Non-recoverable
from Less Severe
• Transition to Critical from Non-
recoverable
• Thermal Trip
• Processor Automatically
Throttled
• Processor Presence Detected
• State Asserted
• Device Enabled
• Transition to OK
• Transition to Non-Critical from
OK
• Transition to Non-Critical from
More Severe
• Monitor
• Informational
Service action
Replace system processor CPU 2.
Go to "5104-22C or 9006-22C
locations" on page 63,
"9006-12P locations" on page
75, or "9006-22P locations" on
page 91 to identify the physical
location and removal and
replacement procedure.
No service action is required.