Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
• CPU Core Func 37 (0x5C)
• CPU Core Func 38 (0x5D)
• CPU Core Func 39 (0x5E)
• CPU Core Func 40 (0x5F)
• CPU Core Func 41 (0x60)
• CPU Core Func 42 (0x61)
• CPU Core Func 43 (0x62)
• CPU Core Func 44 (0x63)
• CPU Core Func 45 (0x64)
• CPU Core Func 46 (0x65)
• CPU Core Func 47 (0x66)
• CPU Core Func 48 (0x67)
Event description
• IERR
• Transition to Non-recoverable
• Predictive Failure
• FRB1 BIST Failure
• FRB2 Hang In POST Failure
• FRB3 Processor Startup
Initialization Failure
• Configuration Error
• SMBIOS Uncorrectable CPU
Complex Error
• Processor Disabled
• Terminator Presence Detected
• Machine Check Exception
• Correctable Machine Check
Error
• State Deasserted
• Device Disabled
• Transition to Critical from Less
Severe
• Transition to Non-recoverable
from Less Severe
• Transition to Critical from Non-
recoverable
• Thermal Trip
• Processor Automatically
Throttled
• Processor Presence Detected
• State Asserted
• Device Enabled
• Transition to OK
• Transition to Non-Critical from
OK
• Transition to Non-Critical from
More Severe
• Monitor
• Informational
Beginning troubleshooting and problem analysis 37
Service action
Replace system processor CPU 2.
Go to "5104-22C or 9006-22C
locations" on page 63,
"9006-12P locations" on page
75, or "9006-22P locations" on
page 91 to identify the physical
location and removal and
replacement procedure.
No service action is required.