Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
• CPU Func 1 (0x0C)
• CPU Func 2 (0x0E)
Event description
• IERR
• Transition to Non-recoverable
• Predictive Failure
• Thermal Trip
• FRB1 BIST Failure
• FRB2 Hang In POST Failure
• FRB3 Processor Startup
Initialization Failure
• Configuration Error
• SMBIOS Uncorrectable CPU
Complex Error
• Processor Disabled
• Terminator Presence Detected
• Processor Automatically
Throttled
• Machine Check Exception
• Correctable Machine Check
Error
• State Deasserted
• Device Disabled
• Transition to Critical from Less
Severe
• Transition to Non-recoverable
from Less Severe
• Transition to Critical from Non-
recoverable
• Processor Presence Detected
• State Asserted
• Device Enabled
• Transition to OK
• Transition to Non-Critical from
OK
• Transition to Non-Critical from
More Severe
• Monitor
• Informational
Beginning troubleshooting and problem analysis 29
Service action
If the sensor name is CPU Func 1,
replace CPU 1. If the sensor
name is CPU Func 2, replace CPU
2. Go to "5104-22C or 9006-22C
locations" on page 63,
"9006-12P locations" on page
75, or "9006-22P locations" on
page 91 to identify the physical
location and removal and
replacement procedure.
No service action is required.