IBM Power System Series Problem Analysis, System Parts, And Locations page 34

Hide thumbs Also See for Power System Series:
Table of Contents

Advertisement

Table 8. OEM record de specific log information and service action (continued)
OEM record de specific log information
3Fxxxxxxxxxx
4Dxxxxxxxxxx
4Fxxxxxxxxxx
55xxxxxxxxxx
56xxxxxxxxxx
5Cxxxxxxxxxx
5Dxxxxxxxxxx
5Exxxxxxxxxx
This ends the procedure.
4. Scan the SELs for an event with the value OEM record df. Did you find a SEL with the value OEM
record df?
If
Yes:
No
5. One or more events might be logged around the same time as the event with the value OEM record
df. These events require a service action if they meet the following criteria:
• A service action keyword is present. For a list of service action keywords, see "Identifying service
action keywords in system event logs" on page 23.
• Asserted is in the description.
• OEM record is not in the description.
• The event has a time stamp close to the time stamp of the event with the value OEM record df.
6. Did you find any SEL events that require a service action as defined in step "5" on page 20?
If
Yes:
20 Power Systems: Problem analysis, system parts, and locations for the 5104-22C, 9006-12P, 9006-22C, and
9006-22P
Then
Continue with the next step.
Go to step "10" on page 21.
Then
Continue with the next step.
Service action
Go to "EPUB_PRC_POWER_ERROR isolation
procedure" on page 56.
Go to Getting fixes and update the system
firmware to the most recent level of firmware
that is available. If this SEL event continues to be
logged, go to "Collecting diagnostic data" on
page 60. Then, go to "Contacting IBM service
and support" on page 61.
Go to "EPUB_PRC_MEMORY_UE isolation
procedure" on page 56.
Go to "EPUB_PRC_HB_CODE isolation
procedure" on page 57.
Go to "EPUB_PRC_TOD_CLOCK_ERR isolation
procedure" on page 58.
Go to "EPUB_PRC_COOLING_SYSTEM_ERR
isolation procedure" on page 59.
Go to Getting fixes and update the system
firmware to the most recent level of firmware
that is available. If this SEL event continues to be
logged, go to "Collecting diagnostic data" on
page 60. Then, go to "Contacting IBM service
and support" on page 61.
Go to Getting fixes and update the system
firmware to the most recent level of firmware
that is available. If this SEL event continues to be
logged, go to "Collecting diagnostic data" on
page 60. Then, go to "Contacting IBM service
and support" on page 61.