Festo EHPS LK Series Instructions & Operating page 29

Parallel gripper
Hide thumbs Also See for EHPS LK Series:
Table of Contents

Advertisement

Malfunctions
LED red "Error"
LED green
"Ready"
Off
Off
Flashes
red
Flashes
red
red on
Off
Tab. 27 LED display
Festo — EHPS-...-LK — 2019-08
Meaning
Off
IO-Link Supply voltage is not connected
Communication not active.
Illumin-
Actuator ready for operation (Fallback, SIO Mode)
ated green
IO-Link Supply voltage: connected
IO-Link Communication: not active
Actuator supply voltage: connected
Illumin-
IO-Link Supply voltage: connected
ated green
IO-Link Communication: not active
Actuator supply voltage: not connected
Flashes
IO-Link Supply voltage: connected
green
IO-Link Communication: active
Actuator supply voltage: not connected
Flashes
IO-Link Supply voltage: connected
green
IO-Link Communication: active
Actuator supply voltage: connected
"ErrorNumber" and "ErrorCode" is output
Flashes
IO-Link Supply voltage: connected
green
IO-Link Communication: active
Actuator supply voltage: connected
 IO-Link-
è