Fault Clearance Io-Link - Festo EHPS LK Series Instructions & Operating

Parallel gripper
Hide thumbs Also See for EHPS LK Series:
Table of Contents

Advertisement

IO-Link Interface description
Name
[Open Gripper]
Tab. 24 System Commands
9.12

Fault clearance IO-Link

Parameters "ErrorNumber"
Diagnostic
Device status
message
Hex (Dec)
0x0 (0)
0x100
Outside the spe-
(256)
cification
0x101
Out of specifica-
(257)
tion (drive can no
longer be moved)
0x102
Out of specifica-
(258)
tion (drive can no
longer be moved)
0x010A
Outside the spe-
2)
(266)
cification
Festo — EHPS-...-LK — 2019-08
Description
With previous release, this com-
mand can initiate a movement of the
gripper jaws in the direction of
"opening".
Error
Possible cause
"Status ok,
device is ready"
"Power supply
error"
"Temperature
too high"
"Temperature
Ambient temper-
too low"
ature too low
"Actuator under
voltage during
movement"
Index
0x0002
Remedy
Actuator
Testing the actu-
supply not
ator supply
connected
voltage
Cable break
Actuator
supply not
sufficient
Ambient
ensure adequate
temperature
pressurisa-
too high
tion/cool-
Gripper has
ing/connection
overload
ensure sufficient
operating tem-
perature
Actuator
Check grip-
supply
ping force,
unstable
check power
Line resist-
supply and
ance
peak load
increased
(faulty sup-
ply cable)
Value
162
"Error-
Count"
1)
No
Yes
Yes
Yes
No
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehps-20-a-lkEhps-16-a-lkEhps-25-a-lk

Table of Contents