IO-Link Interface description
Diagnostic
Device status
message
Hex (Dec)
0x309
Outside the spe-
(777)
cification
0x30D
Outside the spe-
(781)
cification
0x30F
Outside the spe-
(783)
cification
0x310
Outside the spe-
(784)
cification
0x311
Outside the spe-
(785)
cification
0x312
Outside the spe-
(786)
cification
0x400
Failure
(1024)
2)
Festo — EHPS-...-LK — 2019-08
Error
Possible cause
"GrippingPosi-
Process data
tion not latched"
sent by the mas-
ter have been
changed
"GrippingForce
Process data
not latched"
sent by the mas-
ter have been
changed
"GrippingToler-
Process data
ance not
sent by the mas-
latched"
ter have been
changed
"GrippingMode
Process data
not latched"
sent by the mas-
ter have been
changed
"WorkpieceNo
Process data
not latched"
sent by the mas-
ter have been
changed
"Initial hand-
After a cold start,
shake missing"
a single data
migration by
"Latch-
Data"("Control-
Word" = 1) is
required.
"Gripper
–
blocked"
–
Remedy
Transfer of the
changed para-
meters by
"LatchData."
Transfer of the
changed para-
meters by
"LatchData."
Transfer of the
changed para-
meters by
"LatchData."
Transfer of the
changed para-
meters by
"LatchData."
Transfer of the
changed para-
meters by
"LatchData."
Transfer of the
changed para-
meters by
"LatchData."
Gripper is
–
Restoring
difficult to
the free
move
movement of
The travel
the gripper
path of the
–
Service Festo
grab is
AG & Co. KG
impaired
"Error-
Count"
1)
No
No
No
No
No
No
Yes
27