[FIG.126] Dry - Humidity sensor
correction screen
7.1.2 Correct Dry/Web bulb sensor
Setting item
Humi.C.RNG.
Set up dry/web bulb temperature range.
Dry Temp.
Displays temperature of dry bulb temp.
Wet Temp
Displays temperature of wet bulb temp.(removal gauze)
Rel. Humidity
Displays relative humidity (% R.H.)
Press Dry/Wet Bulb ADJ and it shows the temperature difference between dry
bulb & wet bulb. It very important to correct Dry/Wet Bulb because relative
D/W Adjust
humidity measurement is based on the temp. difference between two sensors.
Correction will be performed when pressing it.
Adjust Mode
Initializes to the value before correction.
ADJ. INIT
•Before correction, please remove gauze in the wet bulb sensor and put into
correction mode when measurement value of dry/wet bulb is stabilized.
7.1.3 Range Setting
T.SV range
H.SV range
Temp. Res.
Burnout wait time
A/T Button
In order to prevent mistake of user input setting, Input temp.range when
restricting temp. SV within its desired range.
In order to prevent mistake of user input setting, Input humidity range when
restricting humidity. SV within its desired range.
Select Temp. process value and SV as 0.01 ℃ or 0.1 ℃.
Set up delayed action time after detecting sensor loof brake.
It shows or hides Auto Tuning button in Operation Screen.