Error diagnostics

8.3 Logon to the configuration interface is denied

8.3
Logon to the configuration interface is denied
Error message
"The TS Adapter IE is not allowing any further logon at present. Try again later."
Possible cause
A user is already logged on to the TS Adapter IE. The TS Adapter IE is therefore busy. No
further logon is possible.
Remedy
1. Take one of the following actions:
2. If none of the actions work, switch the TS Adapter IE OFF and back ON at the external
68
– Click "Logout" to close a running session.
– If a direct connection session was ended without "Logout", wait at least 10 minutes.
Then log back on to the TS Adapter IE.
power supply.
TS Adapter IE
Manual, 11/2010, A5E00977705-03