9.6 Mechanical And Climatic Ambient Conditions For Operation Of The Ts Adapter Ie - Siemens SIMATIC TS Adapter IE Manual

Industrial software engineering tools
Table of Contents

Advertisement

9.6
Mechanical and Climatic Ambient Conditions for Operation of the TS
Adapter IE
Operating conditions
The TS Adapter IE is designed for weather-protected, stationary use. The TS Adapter IE
complies with the operational requirements to DIN IEC 60721-3-3:
● Class 3M3 (mechanical requirements)
● Class 3K3 (climatic ambient conditions)
Operation with additional measures
In the following environments the TS Adapter IE must not be operated without additional
measures:
● In locations with high levels of ionizing radiation
● In locations subject to difficult operating conditions, such as dust, aggressive fumes or
● In installations requiring special monitoring, such as elevators and electrical systems in
A suitable additional measure might be installation of the TS Adapter IE in a cabinet or
cubicle for example.
Mechanical ambient conditions
The table below sets out the mechanical ambient conditions for the TS Adapter IE in the
form of sinusoidal vibration.
Table 9- 4
Frequency range in Hz
5 ≤ f < 9
9 ≤ f < 150
Reduction of vibration
Where the TS Adapter IE is subject to major shock impact or vibration, you must take
suitable measures in order to reduce the acceleration or amplitude.
TS Adapter IE
Manual, 11/2010, A5E00977705-03

9.6 Mechanical and Climatic Ambient Conditions for Operation of the TS Adapter IE

gases, severe electrical or magnetic fields
high risk areas
Mechanical ambient conditions
Test values
3.5 mm amplitude
9.81 m/s
constant acceleration
2
Specifications