Working with the TS Adapter IE

7.9 Opening the Configuration Interface

7.9
Opening the Configuration Interface
To open the configuration interface you have the following options:
● Open the configuration interface by direct connection with TeleService (Page 54)
● Opening the configuration interface by direct connection in a browser (Page 55)
● Open the configuration interface via a remote connection with TeleService (Page 56)
● Opening the configuration interface in a browser via a remote connection (Page 57)
7.9.1

Opening the Configuration Interface by Direct Connection with TeleService

Requirement
● You have already set the IP parameters of the TS Adapter IE.
● The IP address of your PG/PC's interface card is in the same subnet as the IP address
Procedure
1. Connect the TS Adapter IE via an Ethernet cable to your PG/PC.
2. Connect the TS Adapter IE to your power supply.
3. Select the TeleService menu command "Options > Administrate TS Adapter IE ..."
4. Select the TS Adapter IE based on its MAC address and confirm with OK.
5. Enter your user name and password in the "Administrate TS Adapter IE" dialog box:
6. Click "Logon".
Result
You see the configuration interface start screen.
See also
Power Supply (Page 27)
54
you assigned to the TS Adapter IE.
If more than one TS Adapter IE is connected to your PG/PC's interface card, the "Select
TS Adapter IE" dialog box opens.
– User: Default "Administrator"
– Password: Default "admin"
TS Adapter IE