Blodgett Export Series Installation And Operation Manual page 9

Gas and electric
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
GAS HOSE RESTRAINT (GAS MODELS)
If the oven is mounted on casters, a commercial flexible
connector with aminimumof 1.9 cm inside diameter must
be used along with a quick connect device.
1. Mount the supplied bracket to the leg bolt just below
the gas inlet.
2. Attach the clip on restraining cable to the mounting
bracket.
Restraint Cable
Bracket
Double stacked unit shown
Figure 7
Back of Oven
VENTILATION (GAS MODELS)
A mechanically driven, canopy type exhaust hood is re-
quired. The hood should completely cover the oven with
an overhang of at least 15 cm on all sides not adjacent to
a wall. The distance from the floor to the lower edge of the
hood should not exceed 2.1m.
WARNING!!
Failure to properly vent the oven can be haz-
ardous to the health of the operator and may
result in operational problems, unsatisfactory
baking and possible damage to the equipment.
Damage sustained as a direct result of im-
proper ventilation will not be covered by the
manufacturer's warranty.
Ovens ordered for hood venting are supplied with a draft
diverter. Install the draft diverter as follows:
1. Place the diverter over the flue connector with the
open area facing the front of the oven.
2. Secure with the sheet metal screws provided.
Front of Oven
7
Installation
Oven Assembly
Draft Diverter
Figure 8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents