Exit/Entry; Example Parameters; Installation; Configuration And Optimization - Motorola FX7400-22350A30-US Integrator Manual

Rfid readers
Table of Contents

Advertisement

Exit/Entry

Example Parameters

The reader reads 20 tags moving at 4 - 7 feet per second at distances up to 8 feet. The read duration is
approximately 7 seconds.

Installation

Two AN480 antennas are installed in a single-sided portal configuration. One antenna is mounted 2.5 feet
above the floor and the second is 4 feet above the floor.
The reader is mounted within 20 feet from the antennas (see

Configuration and Optimization

Reader power: 30 dBm
Reader profile or tag population: Small (see
Session: Session 1

Transition/Impact Door

Example Parameters
The reader reads 200 tags moving at 2 - 4 feet/second for seven seconds.
Installation
Four AN480 antennas are installed in a double-sided portal configuration. One pair of antennas is mounted
two feet above the floor and the second pair is five feet above the floor.
The distance of the portals is 10 feet.
The reader is mounted within 20 feet of the antennas (see
Configuration and Optimization
Reader power: 30 dBm
Reader profile or tag population: Large (see
Session: Session 2
Chapter 3, Installation and
Reader Profiles on page
4-27)
Chapter 3, Installation and
Reader Profiles on page
4-27)
Installation Examples
Communication).
Communication).
5 - 3