Output Word Am.0 "Module Control" [Modul Control] - Festo MSE6-C2M Manual

Energy efficiency module
Hide thumbs Also See for MSE6-C2M:
Table of Contents

Advertisement

Input/output data
8.2.1

Output word Am.0 "Module control" [Modul control]

Output word Am.0 is used to control the pressure regulation and blocking function as well as the con-
sumption measurement.
Data format of output word "16 bits, right-justified"
D15
D14 D13 D12 D11 D10 D9
B15
B14 B13 B12
MSB
Abbreviations used
B0
Shut-off valve controller
B1
Auto-user controller
B2
Q_low-Timer-Reset
B3, B4
Selection of user target pressure
B5
Auto enable controller
B6
Electrical controller output 0
B7
Electrical controller output 1
B12
Consumption V0 Run
B13
Consumption V0 Reset
B14
Consumption V1 Run
B15
Consumption V1 Reset
––
Reserved data bits
D0 
 D15
16 bit output data field
...
MSB/LSB
Most significant bit /least significant bit
Tab. 15 Data format of output word Am.0
Output data, pressure regulation and blocking function
Data bit B0 has the following values:
0 = open shut-off valve - (pressurisation state, default)
1 = closed shut-off valve (blocking state)
Data bit B1 has the following values:
0 = operating mode "User-controlled pressure regulation and blocking function" active (default)
1 = operating mode "Automatic pressure regulation and blocking function" active
Data bit B2 has the following values:
0 = no change in status of the Q_low-Timers (default)
1 = Resetting the Q_low-Timers
42
D8
D7
D6
D5
D4
B7
B6
B5
B4
Festo — MSE6-C2M — 2019-03
D3
D2
D1
D0
B3
B2
B1
B0