Table 3-1. Effect of Speed Limit Settings on Data Rate.
Max rate
setting, bps
14,400
1
19,200
12,000
1
9600
7200
2
4800
300 to 2400
EIA-CTRL
300 to 19,200
EIA-CTRL
300 to 19,200
EIA-CTRL
xx
xx Does not matter—setting does not affect data rate.
1
Both 14,000 and 12,000 bps rates are available for the modem.
7200 bps is available only if V.32bis mode is enabled (via Summary Setup,
2
V.32 Mode option).
3
9600 bps if EIA pin 23 is high, 4800 bps if pin 23 is low.
4
If SYNC AFTER DIAL is enabled (using the &Q1 command), the rate will be
negotiated between the autobaud speed and 1200 bps.
CHAPTER 3: Options: Customizing the Modem Setup
Dialer
option
Leased line modes
xx
xx
xx
xx
xx
xx
xx
xx
Dial modes—Answering
xx
xx
Dial modes—Originating
OFF or DTR
OFF or DTR
HAYES
4
Resultant data rate, bps
14,400
1
19,200
12,000
1
9600
7200
2
4800
2400
9600 or 4800
3
Negotiated between min.
and max. setting
9600 or 4800
3
Negotiated between min.
and max. setting
9600 or 4800
3
Negotiated between autobaud
speed and minimum setting
on originate modem
4
45