Table 5. Clustered gateway installation checklist (continued)
Task
Description
U
6–1
Configure the TSSC's communication settings.
h
Section 7: Perform RAS package configuration and verification
7–1
Configure the RAS package on the server.
h
7–2
Perform RAS verification. Includes verifying
h
attached systems and testing Call Home.
Section 8: SSR releases the system to trained ProtecTIER specialist or LBS representative
8–1
Configure ProtecTIER and create the file
h
system.
8–2
Install the ProtecTIER Replication Manager
h
application, if applicable.
8–3
Install ProtecTIER Manager and create the
h
repository.
|
| | |
8–4
Test the clustered system. Includes checking
h
|
|
system health status.
|
8–5
Turn the system over to the customer. If
h
replication is being used, advise the customer
that it is their responsibility to create and
configure the replication grid.

Installing the server

Installing the TSSC and Ethernet switch
22
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide
About this task
Use this procedure to install the serve.
Important: The customer is responsible for ensuring that any recommended
hardware components that were not included in the purchase of the TS7650G, such
as disk controllers and disk expansion module, are installed in a frame, cabled, and
fully configured; before server installation begins.
Procedure
1. If any components installed in the server and/or disk storage frames are
powered-on, have the customer suspend all I/O activity, and then power-off
the components.
2. Physically install the server (or both servers, in a clustered gateway
configuration) into the server frame.
3. Once physical installation and labeling is complete, go to "Installing the TSSC
and Ethernet switch."
Before you begin
Important: If the customer purchased a TSSC, you are required to install it and its
related components, along with the other gateway hardware. Failure to do so will
prevent the use of Call Home or IBM remote support.
Where to find information
Chapter 5, "Setting up the TSSC for use with
the TS7650G," on page 43.
Chapter 6, "Configuring the RAS package," on
page 49.
Chapter 7, "RAS verification," on page 57.
Chapter 8, "Configuring ProtecTIER using
ptconfig," on page 61.
Chapter 9, "Enabling the ProtecTIER
Replication Manager," on page 69.
Chapter 10, "Installing ProtecTIER Manager,"
on page 71.
Chapter 14, "Testing a clustered system," on
page 97 and "Performing a system health
check" on page 99.
N/A

Advertisement

Table of Contents
loading

This manual is also suitable for:

System storage ts7650g protectier

Table of Contents