Using The Tssc Or A Service Laptop; Service Laptop To Rsa Connection - IBM System Storage TS7600 ProtecTIER Series Installation Roadmap Manual

Hide thumbs Also See for System Storage TS7600 ProtecTIER Series:
Table of Contents

Advertisement

10. For the OS USB selection, choose: Linux OS.
11. Press the down-arrow key to highlight Save Values and Reboot RSA and
12. Press Esc three times.
13. Select Save Settings.
14. When the save is complete, exit the Configuration/Setup Utility screen.
15. Return to the procedure that sent you here.

Using the TSSC or a service laptop

Procedure
Figure 35. Service laptop to RSA connection
114
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide
7. For the Static IP Address, change the last octet to an address value that is
lower than the default of 254.
For example: 172.31.1.253.
8. For the Netmask, enter: 255.255.255.0.
9. Leave the Gateway field blank.
then press <enter>.
The system will pause for a few moments while the RSA reboots. When the
reboot completes, a pop-up message displays.
You are returned to the Configuration/Setup Utility screen.
The server reboots and Server B's RSA IP address is now unique.
1. If you are using the TSSC, skip ahead to step 10 on page 115. Otherwise,
continue with step 2.
2. Connect an Ethernet cable from the Ethernet port on your laptop to the SYS
MGMT (RSA port) on Server B. See Figure 35.
3. On the laptop, click Start → Control Panel.
4. Double-click Network Connections.
5. Right-click Local Area Connection → Properties. See Figure 36 on page 115.