device: eth3
driver: e1000e
desc: "Intel Corporation 82571EB Gigabit Ethernet Controller"
network.hwaddr: 00:15:17:94:41:15
--
device: eth4
driver: bnx2
desc: "Broadcom Corporation NetXtreme II BCM5709 Gigabit Ethernet"
network.hwaddr: 00:1a:64:db:36:24
--
device: eth5
driver: bnx2
desc: "Broadcom Corporation NetXtreme II BCM5709 Gigabit Ethernet"
network.hwaddr: 00:1a:64:db:36:26
Note: The hwaddrs are specific to the Ethernet cards in each system.
2. Use ethtool to verify the following:
For eth0 and eth5: Speed = 100Mb/s or 1000Mb/s
For eth1 and eth2: Speed = 1000Mb/s
For eth3 and eth4: Speed = 100Mb/s or 1000Mb/s
For eth0 and eth5 (Stand-alone): Link detected = yes
For eth0, eth1 eth2 (Clustered): eth3, eth4 (Replication) and eth5 (TSSC): Link
detected = yes
For example:
# ethtool eth1
Settings for eth1:
Supported ports: [ TP ]
Supported link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full 1000baseT/Full
Supports auto-negotiation: Yes
Advertised link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
Advertised auto-negotiation: Yes
Speed: 1000Mb/s
Duplex: Full
Port: Twisted Pair
PHYAD: 1
Transceiver: internal
Auto-negotiation: on
Supports Wake-on: d
Wake-on: d
Current message level: 0x00000001 (1)
Link detected: yes
54