Weidmuller IE-SR-2GT-LAN Manual page 74

Industrial security router/firewall
Table of Contents

Advertisement

Default gateway
Only for Router 3
Operational mode:
IP address parameters WAN Port:
IP address parameters LAN Port:
Default gateway
► Click button "Apply settings" to activate the new settings.
Now the configured parameters will be activated (but not saved). After a few seconds the web interface displays the
new IP addresses as shown in Figure 3. Please keep in mind that now the Router connection is lost due to changing the
IP address range of your connected WAN port.
Figure A4-3: Display of activated new IP addresses of LAN and WAN port
5. Change the IP address of configuration PC
► To reconnect to the Router now change the IP address of the PC to an IP address of the new IP address
range 172.16.1.0/16
For re-connecting to Routers 1 and 2 chose e.g. IP address 172.16.1.100 and subnet mask 255.255.0.0. The input field
"Standard-Gateway" can be left empty.
Copyright © 2013 Weidmüller Interface GmbH & Co. KG
All rights reserved. Reproduction without permission is prohibited.
192.168.21.254
255.255.255.0 (Class C)
NAT (masquerading) not set (leave checkbox empty)
172.16.1.254 (Router of the production network)
IP Router
static
10.1.1.254
255.255.0.0 (Class B)
NAT (masquerading) not set (leave checkbox empty)
static
172.16.1.254
255.255.0.0 (Class B)
NAT (masquerading) not set (leave checkbox empty)
leave field empty (not necessary in this example)
Screenshot of Router 1 show-
ing changed IP addresses
74 / 103