Figure A1-7: Menu System  Backup settings after saving the configuration
► Click on button "Download settings" to write the configuration file to the PC hard disk (Backup file has the default
extension *.cf2")
Now the configuration of the Router is finished!
Testing the accessibility between Ethernet Devices of both networks
1. Run 3 Ping commands from a device of Ethernet network 1 (192.168.10.0/24) using below described
addresses (members of network 2)
 ping 192.168.20.100
 ping 192.168.20.101
 ping 192.168.20.102
Result: All sent "pings" should be answered by the requested IP addresses correctly.
2. Run 3 Ping commands from a device of Ethernet network 2 (192.168.20.0/24) using below described
addresses (members of network 1)
 ping 192.168.10.100
 ping 192.168.10.101
 ping 192.168.10.102
Result: All sent "pings" should be answered by the requested IP addresses correctly.
Note:
1. If you perform the ping test using PC's please check your firewall configuration to ensure that ping re-
quests and echoes are allowed.
2. Keep in mind that every device which will be used for ping testing needs an entry for the standard gateway
(IP address is pointing to the Router of the PC's network)
Copyright © 2013 Weidmüller Interface GmbH & Co. KG
All rights reserved. Reproduction without permission is prohibited.