Device Connection; Power Supply; Read/Write Head And Trigger Sensors - Pepperl+Fuchs IC-KP-R2-V1 Manual

Identcontrol interface with serial interface
Table of Contents

Advertisement

IC-KP-R2-V1
Installation
5.4

Device connection

Electrical connection using plug connectors makes installation simple.
5.4.1

Power supply

Connect the power supply via an M12 connector with integrated voltage and reverse polarity
protection indicator (green: correct polarity, red: reverse polarity). A plug with the following pin
assignment is located on the housing:
4
1
2
1
+ 24 V
2
NC
3
GND
4
NC
Power supply AIDA
Connect the power supply for the IDENTControl using a connector that conforms with AIDA. A
plug with the following pin assignment is located on the housing:
1 2 3 4 5
1
+ 24 V
2
GND
3
n.c.
4
n.c.
5
n.c.
Compatible connecting cable see chapter 4.7.2.
5.4.2

Read/Write Head and Trigger Sensors

A maximum of 4 read/write heads can be connected to the IDENTControl.
Instead of the read/write heads, a maximum of 2 trigger sensors can be connected to sockets 3
and 4. A trigger sensor can be assigned to only one read/write head. The trigger sensors must
be PNP.
Connect the read/write heads and trigger sensors to the sockets on the top of the enclosure
using M12 connectors.
2
1
4
For details of compatible read/write heads and of compatible connecting cables, see chapter
4.7.1.
3
1
+
2
A
3
-
3
4
B
5
5
trigger switch
+
signal
-
15