Pepperl+Fuchs IC-KP-R2-V1 Manual page 37

Identcontrol interface with serial interface
Table of Contents

Advertisement

IC-KP-R2-V1
Commands
Write read only code IPC11 and IDC-..-1K
"Read-after-write" operating mode is not used.
Tags IPC11 can be programmed to behave like the IPC02 read only tag. To do this, use the
commands SX and EX. The code is read when tag type '02' or '11' is set with the commands SF
and EF.
Tags IDC-...- 1K can be programmed to behave like the ICC read only tag. This programming
occupies the first 8 bytes in the tag and occurs when the tag type '50' is set with the commands
SX or EX.
This code is read when tag type '52' is set with the commands SF or EF. If you use the
command SF or EF when tag type '50' is selected, the 4-byte read only code of the tag is
issued.
Single write read only code (SX):
Command:
Response:
The R/W head makes only one attempt to write a read only code.
IPC11:
IDC-...-1K:
1. The first 3 bytes are hexadecimal (0h ... Fh), the last 4 bytes are decimal (0d ... 9d).
For example:
The following command describes an MCV60 data carrier with the four-digit ID code '1234' on
channel 1:
SX 1 60 04 1234 # <CR>
SX
1
60
04
1234
#
<CR>
Enhanced buffered write read only code (EX):
0 1 # <CR>
0
1
#
<CR>
Command:
Response:
SX <Ident channel><FixType><FixLen><Data><CHCK><ETX>
<Status><Ident channel><CHCK><ETX>
<FixLen>
=
5
<FixType>
=
'02' ASCII (30h 32h), the read only code cannot be
changed
'11' ASCII (31h 31h), the read only code can be
overwritten
<FixLen>
=
1
7
<FixType>
=
'52' ASCII (35h 32h), the read only code can be
overwritten
Single write read only code command
Channel 1
Read only code type
Read only code length
Read only code
End character
End character
Status
Channel 1
End character
End character
EX <Ident channel><FixType><FixLen><Data><CHCK><ETX>
<Status><Ident channel><CHCK><ETX>
37