Run Mode

The ADM will start in the Run screens at the "Home" screen. Press
Mode screens. .
Or press
to access the Setup screens.
Home — System Off
This is the home screen when the system is off.
This screen displays actual temperatures, actual
pressures at the fluid manifold, jog speed, coolant
temperature, and number of cycles.
Home — System Active
When the system is active, the home screen displays
actual temperature for heat zones, actual pressures
at the fluid manifold, coolant temperature, jog speed,
the number of cycles, along with all associated
control soft keys.
Use this screen to turn on heat zones, view
coolant temperature, start the proportioner, stop the
proportioner, park the component A pump, enter jog
mode, and clear cycles.
332636C
to navigate through the Run
Home — System With Error
Active errors are shown in the status bar. The error
code, alarm bell, and description of the error will
scroll in the status bar.
1. Press
to acknowledge the error.
2. See
Troubleshoot Errors, page 72
action.
Targets
Use this screen to define the setpoints for the
A Component Temperature, B Component
Temperature, heated hose temperature, and
pressure.
Maximum A and B temperature for systems without
booster heat: 150°F (65°C)
Maximum A and B temperature for systems with
booster heat: 180°F (82°C)
Maximum heated hose temperature: 10°F (5°C)
above the highest A or B temperature setpoint or
180°F (82°C).
Note
If the remote display module kit is used,
these setpoints can be modified at the gun.
Operation
for corrective
53