Install Wall (Optional) - Graco Reactor 2 Series Operation

Elite integrated proportioning system
Table of Contents

Advertisement

Install Wall (optional)

It is only possible to install a wall between the
proportioner and generator for systems without an air
compressor.
Benefits:
• Temperature condition the trailer space where
chemical is stored. Check with chemical
manufacturer for chemical storage temperatures.
• Reduce noise for the operator while the Reactor
is running.
The supplied fuel lines and battery cable may need
to be replaced if a wall is installed between the
proportioner and generator. Purchase the Fuel Line
and Battery Cable Extension Kit 24K333.
1. If necessary drain coolant from system. See
Reactor repair manual for complete instructions.
Coolant lines do not need to be disconnected to
install a wall.
Note
Battery must be connected to starter to
drain coolant from system.
2. Remove screws and battery bracket from the
pallet.
Remove Battery Bracket and Fuel Tank
Figure 21
332636C
3. Remove fuel tank from the pallet.
a. Remove the mounting screws, supports, and
spacers.
b. Disconnect inlet and outlet fuel lines from the
fuel tank.
c. Use two people to lift fuel tank off of the pallet
and place where the fuel fill spout is easily
accessible.
Note
Do not mount fuel tank in front of
the generator air intake or where it
will limit opening and access to the
electrical enclosure (DB).
4. Install wall (IW) where the fuel tank was located.
Ensure there is at least 1.25 in. (31.75 mm)
between the wall and exhaust muffler. See
Fig.
22.
Note
To prevent an air pocket from forming
inside the coolant lines between the
proportioner and generator, ensure
there is a constant rise in elevation if
the coolant lines are adjusted. Failure
to have a constant rise in elevation will
reduce heating efficiency. See
5. Reconnect inlet and outlet fuel lines.
6. Install spacers, supports, and screws through
the fuel tank and tighten to the floor. Torque to
40 ft-lbs (54 N•m).
7. Place battery bracket over fuel tank or near the
Reactor. Remove existing battery cables from
engine and replace with the cables provided from
the fuel line and battery cable extension kit.
8. Install mounting bolts through battery bracket and
tighten to the floor. Torque to 40 ft-lbs (54 N•m).
Note
Pads under the battery bracket help
stabilize the fuel tank during operation.
Setup
Fig.
23.
39