Flushing - Graco Reactor 2 Series Operation

Elite integrated proportioning system
Table of Contents

Advertisement

Flushing

Flushing
To help prevent fire and explosion:
• Flush equipment only in a well-ventilated area.
• Do not spray flammable fluids.
• Do not turn on heaters while flushing with
flammable solvents.
• Flush out old fluid with new fluid, or flush out old
fluid with a compatible solvent before introducing
new fluid.
• Use the lowest possible pressure when flushing.
• All wetted parts are compatible with common
solvents. Use only moisture-free solvents.
70
To flush feed hoses, pumps, and heaters
separately from heated hoses, set PRESSURE
RELIEF/SPRAY valves (SA, SB) to PRESSURE
RELIEF/CIRCULATION
lines (N).
To flush entire system, circulate through gun fluid
manifold (with manifold removed from gun).
To prevent moisture from reacting with
isocyanate, always leave the system filled
with a moisture-free plasticizer or oil. Do not
use water. Never leave the system dry. See
Important Isocyanate Information, page 8
. Flush through bleed
.
332636C