Graco Reactor 2 Series Operation page 60

Elite integrated proportioning system
Table of Contents

Advertisement

Startup
g. Hold gun fluid manifold over two grounded
waste containers. Open fluid valves A and B
until clean, air-free fluid comes from valves.
Close valves.
The Fusion AP gun manifold is shown.
14. Press
to activate the system.
15. Preheat the system:
This equipment is used with heated fluid which
can cause equipment surfaces to become very
hot. To avoid severe burns:
• Do not touch hot fluid or equipment.
• Do not turn on hose heat without fluid in
hoses.
• Allow equipment to cool completely before
touching it.
• Wear gloves if fluid temperature exceeds
110°F (43°C).
60
Thermal expansion can cause
overpressurization, resulting in equipment
rupture and serious injury, including fluid
injection. Do not pressurize system when
preheating hose.
a. Press
to turn on hose heat zone.
b. Wait for the engine to reach operating
temperature, indicated when the black arrow
is under the green area of the temperature
bar. The radiator fan will turn on when
operating temperature is reached.
c. Wait for the hose to reach set point
temperature.
d. Press
to turn on A and B heat zones.
332636C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reactor 2 e-30iReactor 2 e-xp2i

Table of Contents