Models

Models
Reactor 2 E-30i
All base systems include fluid inlet pressure and temperature sensors and Graco InSite
see
Accessories, page
Model
E-30i
Base Machine
272079
Maximum Fluid
2000 (13.8, 138)
Working Pressure
psi (MPa, bar)
Approximate Output
0.0272 (0.1034)
per Cycle (A+B) gal.
(liter)
Max Flow Rate lb/min
30 (13.5)
(kg/min)
Total System Load †
7,400
(Watts)
Voltage (phase)
240 VAC (1)
Available Auxiliary
52 Amps (240)
Current at Volts, 60
Hz*
Fusion AP Package 
AP2079
(Gun Part No.)
(246102)
Fusion CS Package 
CS2079
(Gun Part No.)
(CS02RD)
Probler P2 Package 
P22079
(Gun Part No.)
(GCP2R2)
Heated Hose
24Y240
50 ft (15 m)
Heated Whip Hose
246055
10 ft (3 m)
Total system watts used by system, based on
maximum heated hose length of 310 ft (94.5 m)
for each unit.
*
Full load amps available for auxiliary equipment
when all bare-system components are operating
at maximum capabilities. Available auxiliary
current is based on 310 ft (94.5 m) of heated hose.
An additional 3.0 amps (240 VAC) of auxiliary
current is available for each 50 ft (15.2 m) section
of heated hose that is not used.
Auxiliary current at 120 VAC is available on CB08,
line 1 (circuit breaker pin 2), line 2 current at 120
VAC is used by the air dryer (circuit breaker pin 4).
10
12.
No Air Compressor/Dryer
E-30i with heat
272080
2000 (13.8, 138)
0.0272 (0.1034)
30 (13.5)
11,600
240 VAC (1)
35 Amps (240)
AP2080
(246102)
CS2080
(CS02RD)
P22080
(GCP2R2)
24Y240
246055
With Air Compressor/Dryer
E-30i
272089
2000 (13.8, 138)
0.0272 (0.1034)
30 (13.5)
13,500
240 VAC (1)
22 Amps (240)
9 Amps (120)
AP2089
(246102)
CS2089
(CS02RD)
P22089
(GCP2R2)
24Y240
246055
Available auxiliary current will be less when the
engine is de-rated for site altitude. Reduce the
Available Auxiliary Current in the chart by 2.5
Amps (240 VAC) per 1000 ft (300 m) elevation
increments. If the available auxiliary current is
less than zero, the system configuration may not
support the full load at that altitude.
Includes Complete Air Compressor/Dryer Kit
24U176.
Refer to
Circuit Breaker Configuration Options,
page
33.
See
Approvals, page
Packages include gun, heated hose, and whip
hose.
. For part numbers,
E-30i with heat
272090
2000 (13.8, 138)
0.0272 (0.1034)
30 (13.5)
17,700
240 VAC (1)
5 Amps (240)
9 Amps (120)
AP2090
(246102)
CS2090
(CS02RD)
P22090
(GCP2R2)
24Y240
246055
12.
332636C