Manual Hose Heat Mode

If the system produces the T6DH sensor error hose
alarm or the T6DT sensor error TCM alarm, use
manual hose heat mode until the hose RTD sensor
can be repaired.
Do not use Manual Hose Mode for extended periods
of time. The system performs best when the hose
has a valid RTD and can operate in temperature
control mode. If a hose RTD breaks, the first priority
is to fix the RTD. Manual Hose Mode can help finish
a job while waiting for repair parts.
Enable Manual Hose Mode
1. Disconnect the hose RTD sensor from the TCM.
2. Enter Setup Mode and navigate to System
Screen 2.
3. Select Enable Manual Hose Mode.
Note
When manual hose mode is enabled, the
manual hose mode advisory EVCH-V
will appear.
332636C
4. Enter Run Mode and navigate to the Target
screen. Set the desired hose current.
Hose Current Settings Hose Current
Default
Maximum
Note
Until the RTD sensor is repaired, the
T6DH sensor error alarm will display
each time the system is powered up.
5. Navigate back to the Run Mode Home screen.
The hose now displays a current instead of a
temperature.
Spraying
20A
37A
65