Fluid Circulation
Circulation Through Gun Manifold
NOTICE
To prevent equipment damage, do not circulate
fluid containing a blowing agent without consulting
with your material supplier regarding fluid
temperature limits.
Note
Circulating fluid through the gun manifold
allows rapid preheating of the hose.
1. Install gun fluid manifold (P) on accessory
circulation kit (CK). Connect high pressure
circulation lines (R) to circulation manifold.
The Fusion AP gun manifold is shown.
CK
Gun
246362
Fusion AP
256566
Fusion CS
2. Route circulation lines back to respective
component A or B supply drum. Use hoses
62
3. Follow procedures from
4. Turn main power switch on
5. Set temperature targets. See
6. Press
Jog Mode
Jog mode has two purposes:
• Speed fluid heating during circulation.
• Ease system flushing and priming.
1. Turn main power switch on
2. Press circulate
3. Press up or down
Manual
309818
4. Press
313058
5.
rated at the maximum working pressure of this
equipment.
to circulate fluid in jog mode until
A and B temperatures reach targets. See
Jog Mode, page 62
for more information about
jog mode.
to enter jog mode.
(J1 through J20).
Note
Jog speeds correlate to 3-60% of motor
speed, but will not operate over 700 psi
(4.9 MPa, 49 bar) for either A or B.
to start motor.
To stop the motor and exit jog mode press
or
.
Startup, page
57.
.
Targets, page
53.
.
to change jog speed
332636C