USB Data

Each time a USB flash drive is inserted into the ADM
USB port, a new folder named DATAxxxx is created.
The number at the end of the folder name increases
each time a USB flash drive is inserted and data is
downloaded or uploaded.
Note
The ADM can read/write to FAT (File
Allocation Table) storage devices. NTFS,
used by 32 GB or greater storage devices,
is not supported.

USB Logs

During operation, the ADM stores system and
performance related information to memory in the
form of log files. The ADM maintains four log files:
• Event Log
• Job Log
• Daily Log
• System Software Log
• Blackbox Log
• Diagnostics Log
Follow
Download Procedure, page
log files.
Event Log
The event log file name is 1–EVENT.CSV and is
stored in the DATAxxxx folder.
The event log maintains a record of the last 49,000
events and errors. Each event record contains:
• Date of event code
• Time of event code
• Event code
• Event type
• Action taken
332636C
• Event Description
Event codes include both error codes (alarms,
deviations, and advisories) and record only events.
Actions Taken includes setting and clearing event
conditions by the system, and acknowledging error
conditions by the user.
Job Log
The job log file name is 2–JOB.CSV and is stored
in the DATAxxxx folder.
The job log maintains a record of data points
based on the USB Log Frequency defined
in the Setup screens. The ADM stores the
last 237,000 data points for download. See
Setup - Advanced Screen 3 — USB, page
information on setting the Download Depth and USB
Log Frequency.
• Data point date
• Data point time
• A side heat exchanger temperature
• A side boost heater temperature
• B side heat exchanger temperature
• B side boost heater temperature
79, to retrieve
• Hose temperature
• Engine coolant temperature
• A side temperature setpoint
• B side temperature setpoint
• Hose temperature setpoint
• Inlet A side pressure
• Inlet B side pressure
• Pressure setpoint
• System lifetime pump cycle counts
• Pressure, volume, and temperature units
• Job name/number