Overview - Graco Reactor 2 Series Operation

Elite integrated proportioning system
Table of Contents

Advertisement

Overview

Overview
The system uses two coolant loops to use heat
released from the engine to heat the A and B
component material to the target temperatures
defined on the ADM (PD).
Figure 16 Engine Coolant Loop and Proportioner
Coolant Loop
34
The engine coolant loop (gray) circulates heated
coolant from the engine (EE), through the heat
exchanger (HE), radiator (ER), and back to the
engine. Coolant in the proportioner coolant loop
(black) captures heat from the engine coolant loop
inside the heat exchanger (HE) near the radiator.