Run Mode; Setup Mode; On Time Configuration (Minutes) - Graco G-Mini 25R800 Instructions Manual

Hide thumbs Also See for G-Mini 25R800:
Table of Contents

Advertisement

The controller operates in two modes; RUN MODE and
SETUP MODE. Each mode has multiple functions.

RUN MODE

RUN MODE performs two functions while monitoring
Alert/Alarm conditions: ON TIME and OFF TIME.
In ON TIME the motor is
running and the lubrication
is delivered. ON TIME can
be configured to be active
for a period of time in minutes or a period of lube
cycles (cycle or proximity switch is required).
In OFF TIME the motor is not
running. This is a period
where no lubrication is deliv-
ered. OFF TIME can be con-
figured for 15 / 30 / 45 min. or 1 to 99 hours.
By default, units with controllers are set to operate with
an ON TIME period of five (5) minutes and an OFF
TIME period of one (1) hour.
Once an ON TIME lubrication period
begins, it can be terminated by pressing
the UP arrow/CANCEL button.
While in RUN MODE the controller
monitors Alert/Alarm conditions. See
Alert and Alarm Scenarios, page 27 for full descrip-
tions.
3A6714C

SETUP MODE

Press both the UP and
DOWN arrow buttons
together for 3 seconds to
enter SETUP MODE.
The first digit on the display
begins to blink. This indicates SETUP MODE. After
entering SETUP Mode, if no activity is detected, after 60
seconds a timeout occurs and the controller resumes in
RUN MODE.

ON TIME Configuration (Minutes)

The first configuration in SETUP MODE is programming
the ON TIME.
Notice the following on the controller:
-
The LED next to the
Clock in the ON field illu-
minates.
-
The first digit on the dis-
play begins to blink.
-
A dot on the display
under the MM illumi-
nates.
This confirms that the controller is ready for the first digit
to be configured for ON TIME in Minutes (MM).
NOTE: The ON TIME can be configured between 1 to
30 minutes.
1. Press the UP or DOWN
arrows to select the first
digit.
2. Press the ENTER button
to save the selection.
After the ENTER button is
pressed, the second digit begins
to blink. The ON LED and MM
dot remains lighted.
This confirms that the second
digit for ON TIME is being config-
ured in Minutes (MM).
Controller Operation
21