Led Indicator; Led Indicator Overview - Graco QUANTM i30 Instructions Manual

Table of Contents

Advertisement

LED Indicator

LED Indicator Overview

LED Indicator
Red, solid
Red, flashing
Yellow, solid
Yellow, flashing
Green, solid
Green, flashing
No light (off)
3A8572B
Equipment Status
Powered on, speed set at 0 (zero),
system not operating.
Motor fault, motor error.
Calibrating. Performing startup
sequence.
Leak sensor alert.
Startup sequence complete.
Normal operation.
Normal operation, stalled against
pressure.
System not powered.
Notes
Be aware that the equipment is energized.
To initiate equipment operation, follow Start the
Equipment, page 22.
See Troubleshoot LED Indicator Event Errors,
page 26.
No action. Allow equipment to finish startup
sequence.
Open the fluid drain valve (G) or fluid shutoff
valve (H) to allow the equipment to cycle until
the startup sequence is finished.
See "Leak sensor alert" Troubleshoot LED
Indicator Event Errors, page 27.
To initiate equipment operation, follow Start the
Equipment, page 22.
No action.
Be aware that the equipment is energized.
Special-case action. See Troubleshoot LED
Indicator Event Errors, page 26.
See Troubleshoot LED Indicator Event Errors,
page 26.
LED Indicator
25

Advertisement

Table of Contents
loading

Table of Contents