Installation troubleshooting

Procedure A-14: Removing the SFP modules

...................................................................................................................................................................................................................................
Overview
The procedures described below provide removal instructions for the following SFP
types:
• MSA latch (type 1)
• MSA latch (type 2)
• Bail latch "bottom up" (= type 1)
• Bail latch "top down" (= type 2).
Safety
Electronic components can be destroyed by electrostatic discharge.
Hold SFPs only at the edges. Always observe the ESD instructions (cf.
discharge" (p.
MSA latch (type 1)
Proceed as follows to remove this type of SFP:
...................................................................................................................................................................................................
Put the fibers away from the transceiver.
1
...................................................................................................................................................................................................
Slide the bar back by using a screwdriver (see figure below).
2
Result:
was moved a bit out of its latch.
...................................................................................................................................................................................................
Grep the SFP transceiver with your fingers and pull it out.
3
E
N D
O F
...................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-374-179R10.0
Issue 2, June 2009
CAUTION
ESD hazard
1-20)).
There should be a small click, or it should be visible that the transceiver
S T E P S
Alcatel-Lucent - Proprietary
See notice on first page
"Electrostatic
A-25