Mixed configuration: 1675 LambdaUnite MSS and 1663
ADMu

Procedure D-2: Mounting the 1663 ADMu subrack(s)

...................................................................................................................................................................................................................................
Before you begin
The procedure below describes the mounting of the 1663 ADMu subrack(s). A
maximum of two subracks can be mounted, one at the front and one at the back side
of the rack.
Procedure
Proceed as follows to mount the 1663 ADMu subrack(s):
...................................................................................................................................................................................................
Mount one mounting bracket kit (CC848927224, item 1) on the subrack at mounting
1
position *3 as shown in the figure below.
...................................................................................................................................................................................................
Put the subrack on the bottom of the rack frame (rack front side) and fix it using
2
M6x16 screws (CC901331421) with 7 ± 1.0 Nm [61.96 ± 2.65 lbs-in] torque. Use the
hole positions #47, #58, #65 and #77 (see
LambdaUnite MSS and 1663 ADMu)" (p.
NOTE: The hole numbering is counted from top to bottom of the rack frame.
...................................................................................................................................................................................................
Repeat
3
mounted at the back side of the rack.
E
N D
O F
...................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-374-179R10.0
Issue 2, June 2009
Step 1
and
Step 2
in the case of a second 1663 ADMu subrack which has to be
S T E P S
Alcatel-Lucent - Proprietary
See notice on first page